e-SYNC - Operating Instructions - Realtime Click here for printable version in pdf formatPrint

Screen by Screen  -  Text Format


e-SYNC

The e-SYNC is an electronic surveying instrument that provides inclination and tool-facing readings accurate to ± 0.5 degree.  

The e-SYNC has 4 operating modes: single shot automatic, single shot timed, multishot timed and real-time.

e-SYNC - on/off switch, cable/re-charging port, instrument window         e-SYNC - wireliess antenna window

A - On/Off switch   B - Cable/Recharge Port   C - Instrument Window   D - Wireless Antenna


Handheld Computer The e-SYNC receives its operating commands and reports the survey results to a handheld computer.

The handheld computer has a touch sensitive screen with large, user friendly buttons and text to guide you through the commands required to start and download a survey.  

Communication between the e-SYNC and handheld computer is through wireless “Bluetooth” technology.

Wireless communication can only occur over an obstacle free distance of a few metres, which means that the e-SYNC and handheld computer do not communicate when the instrument is in the hole.
A special connection cable is also provided as a backup means of communication and for use when re-charging the internal batteries. (see operating manual for more details)

When taking a survey, the e-SYNC automatically records the date and time of each survey. After downloading, this information is then stored in the handheld computer for future reference.

Once the survey results are in the handheld computer an export file can be created to view the survey log on other computers.

After downloading your survey results to the handheld computer, you can add additional information to each survey record such as location, depth of hole, operator and any notes you would like to be kept with that particular survey.


top


Step by Step – Operating Instructions - "Realtime Mode"

Turn on the e-SYNC by turning the on/off switch ( A ) (Figure 1) clockwise with the standard screw driver provided.

A flashing “green” light should appear in the instrument window ( C )

If light fails to come on check batteries.

e-SYNC ports
Figure 1

   A - On/Off switch

   B - Cable/Recharge Port

   C - Instrument Window

e-SYNC ports
Figure 2

Turn on the handheld computer.

Press: Start - File explorer - SD Card - Pajari - e-SYNC

Screen Info: – Initializing . . .

Initializing
This brings you to:
Main Menu Screen Screen 1 – Main Menu

This screen gives you 3 options:

  1. Start Advanced

  2. Start Simple

  3. Close Program

Press the “Start Advanced” button

This brings you to:

Connect to / Options Screen

Screen 2 – Connect to / Options Screen

This screen gives you 5 options  

  1. Wireless

  2. Cable

  3. Work with Stored Data

  4. System Settings

  5. Back

Press the “System Settings" button

This brings you to: 

Survey Mode Menu

Screen 32Survey Mode Menu

This screen lists the 4 survey modes available.

This screen also gives you 3 options

  1. Adjust the time settings.

  2. Change the backlight settings of the handheld.

  3. Done will return you to the previous screen.

Select “Real-Time

Press the “Done” button

This brings you to:

Screen 2Connect to / Options Screen

This screen gives you 4 options

  1. Realtime

  2. Work with Stored Data

  3. Survey Settings

  4. Back

Press the “Realtime” button

Screen info: "Please Ensure Realtime cable is plugged into both the e-SYNC and this device."

Press the “OK” button  

This brings you to:

Screen 3 – Instrument Action

This screen gives you 4 options

  1. System Test

  2. Start Survey

  3. Download Survey

  4. Back

 

Press the “Start Survey” button  

Screen info: "Please wait . . . Performing Test"

Screen info

changes to:

 

Performing Test

Before each survey is taken, a system test is automatically performed.

Pressing the “Start Survey” button when there is a previous survey waiting to be downloaded will return the following messages:

Screen info: “Please wait… “

Screen info: “There is a Survey Ready in the e-SYNC.

Please download before starting a new survey”

Press the OK button to return to: Screen 3 - Instrument Action to download the survey.

 

Pressing the “Download Survey” button when no survey has been taken will return the following message:

Screen info: “Please wait… “

Screen info:  No survey ready for download in the e-SYNC.

Please record a survey first, then attempt download again”.

Press the “OK” button to return to: Screen 3 - Instrument Action

 

Pressing the “Back” button takes you to:

Screen 2 - Connect to / Options Screen

This brings you to:

System Test Screen

Screen 4 - System Test

A system test, checks the battery levels of the handheld, the e-SYNC and also checks the electronic sensors inside the e-SYNC to be sure everything is OK before you take the survey. If the test should fail it will be repeated up to two more times. If the battery levels are low a warning screen will appear. 

 

Press the “Done” button  

This will bring you to:

Screen 50 - Realtime Readings Screen

This screen shows you the readings coming from the e-SYNC.

The “stability” indicator shows how much the e-SYNC is moving.

A "green" stability meter means there is no movement with the e-SYNC.

A "red" stability meter means the instrument is moving.

Pressing the "Save" button will record the readings at that moment in time.

Pressing the "Done" button will take you to Screen 2 - Connect to / Options Screen

Press the “Save” button

This brings you to:

Screen 8 - Survey Results Screen  

This screen will appear once for each survey that was taken.

The buttons at the top of this screen allow you to save additional information for example: operator name, location, depth and any notes you would like kept with each survey results.

For instructions on how to add this information click on the link "Adding Survey Information"

Press the “Next” button

This brings you to:

Survey Summary Screen - with all details

Screen 15 – Survey Summary

This screen shows you a summary of all the survey information that will be stored and saved when you press the “Save” button.

Please Note: Once you press the “Save” button you will be no longer able to add or customize any information for that survey.

 

Press the “Save” button

In Realtime survey mode, the above screen will re-appear once for each survey that was taken. 

After all surveys have been saved you will be returned to:

 

Screen 3 - Instrument Action Screen

top

Step by Step – Operating Instructions – Realtime Mode – Text Format


1. Turn on the e-SYNC.
2. Turn on the handheld computer.
3.

Press: Start - File explorer - SD Card - Pajari - e-SYNC

Screen info: - Initializing . . .

4. Press – “Start Advanced”
5. Press – “System Settings”
6. Select Realtime 
7. Press – “Done"
8. Press – “Realtime" button 
9. Press – “OK
10.

Press – “Start Survey”

Screen info:

·         Please wait

·         Performing Test

11. Press – “Done"
12. The readings coming from the handheld computer are now continuous.

Press – “Save" when the e-SYNC as at the survey location and has stopped moving.

13. Press – “Next"
14. Press – “Save"

The last three steps will repeat once for every time you press the "Save" button when on the "Realtime readings screen"

 

 